抄録
In this paper, we report on the design case with the steel rigid frame building that is faced to the elevated railroad of SHINKANSEN. The building is designed for habitable performance based on vibration test.
As the results, the ground vibration by SHINKANSEN is confirmed that specific number of vibrations to depend on train scale and speed excelled. And, we report one example of the office building using the effect of the input loss for improvement of habitable. It is also shown that floor vibration can be forecasted by the simple simulation analysis.