Dental Materials Journal
Online ISSN : 1881-1361
Print ISSN : 0287-4547
ISSN-L : 0287-4547
Original Paper
Bioactive Co-Cr alloy for biomedical applications prepared by surface modification using self-assembled monolayers and poly-γ-glutamic acid
Chao LIUChisato MATSUNAMIYuki SHIROSAKIToshiki MIYAZAKI
Author information
JOURNAL FREE ACCESS

2015 Volume 34 Issue 5 Pages 707-712

Details
Abstract

Cobalt-chromium (Co-Cr) alloys are used in clinical practice for the hard tissue reconstruction because of their favorable biocompatibility and mechanical properties. However, their applications have been limited because of their poor bioactivity, making them poor at bone-bonding. In this study, the bioactivity of a Co-Cr alloy was evaluated following the immobilization of cross-linked poly-γ-glutamic acid (γ-PGA) onto its surface via the formation of 11-aminoundecylphosphonic acid self-assembled monolayers (SAMs). Results of X-ray photoelectron spectroscopy revealed the presence of a new P2p peak, which confirms SAMs formation. Furthermore, the surface became highly hydrophobic following the immobilization with γ-PGA. Subsequent treatment with CaCl2 at 0.5 M or more and soaking in a simulated body fluid led to the formation of a low crystalline apatite. The present results show that chemical modification can be used to induce the formation of an apatite layer on the surface of a Co-Cr alloy in simulated body fluid.

Content from these authors
© 2015 The Japanese Society for Dental Materials and Devices
Previous article Next article
feedback