建物の気密性を用いた換気量の簡易計算法
石田 建一鎌田 元康千田 善孝星川 邦彦林 基哉
著者情報
ジャーナル フリー

1992 年 438 巻 p. 23-31

詳細
抄録
In this paper we present a simplified calculation method of the house infiltration rates with the building air tightness. The characteristic of the method is able to estimate the infiltration rates for combination of out door wind speed and indoor-outdoor temperatuer difference. The proposed calculation method was tested using the measured infiltration data of a experimental house for a year. A results of the comparison between the calculations and measurements showed that the agreement between the prediction and the measurement was also within 0.1 volume par hour.
著者関連情報
© 1992 一般社団法人日本建築学会