パネル化した木造軸組外側気密・断熱住宅の構法計画と性能 : 北海道における木造住宅外断熱構法に関する基礎的研究(その4)
飯田 雅史菊地 弘明
著者情報
ジャーナル フリー

1992 年 439 巻 p. 65-72

詳細
抄録

The purpuse of this paper is to analyze the process of making the panels, the condition of construction, the airtightness and the percentage of the water content of the wooden frame of the house which was constructed with insulating panels from the outside of the laminated wooden frame. The results of this study were as follows : 1) The construction method with panels decreased the man-days for building by 19 in comparison with the traditional method of working at the building site. 2) The percentages of the water content of the wooden groundsill and the wooden frame of panels varied from 5 to 12 % in all season, which means that there is little danger of rotting. 3) The effective open area of the house remained about 2.5cm^2 per floor area for half a year from the moving-in. The airtightness of the house also remained in good condition.