日本建築学会構造系論文集
Online ISSN : 1881-8153
Print ISSN : 1340-4202
ISSN-L : 1340-4202
ダンパーが不均等配置された多層パッシブ制振構造の応答予測
竹内 徹市川 康中島 秀雄笠井 和彦
著者情報
ジャーナル フリー

2004 年 69 巻 583 号 p. 115-122

詳細
抄録

In designing passively vibration-controlled buildings, it is difficult for the designers to evaluate the response with various types of dampers, especially the dampers cannot be distributed uniformly because of architectural limitations. Trial-and-error-based design with time history analyses does not necessarily promote understanding the relationship between damper layout and their effects. The present paper proposes simplified response estimation methods for passively vibration-controlled multistory buildings with elasto-plastic damper and visco-elastic damper systems including non uniform distributions. In these methods various equivalent linearization techniques are introduced, and their accuracies are compared with time-history analyses.

著者関連情報
© 2004 日本建築学会