一端曲げを受けるH形断面鋼柱の曲げねじれ座屈を考慮した構造性能評価手法
佐藤 篤司吉岡 慎平
著者情報
ジャーナル フリー

2022 年 87 巻 796 号 p. 567-578

詳細
抄録

The Architectural Institute of Japan (AIJ) Recommendations specify requirements for H-shaped steel columns forming plastic hinges. However, the Recommendations contain no rationale for determining an acceptable lateral-torsional buckling slenderness ratio due to the direct quotation of the steel beams’ limitation. A previous study clarified that a beam-column susceptible to lateral-torsional buckling could not be properly evaluated by the requirement. Therefore, in this study, an index considering lateral-torsional buckling is proposed. In addition, a plastic deformation capacity evaluation formula, modified requirements, and strength correlation are proposed based on the proposed index.

著者関連情報
© 2022, 日本建築学会