設計基準強度150N/mm^2クラスの高強度コンクリートを用いたタイル先付けPCa部材のタイル接着強度に関する実験的研究(材料施工)
久保田 浩陣内 浩黒岩 秀介渡邉 悟士寺内 利恵子下野 充雄服部 敦志寺嶋 知宏
著者情報
ジャーナル フリー

2006 年 12 巻 24 号 p. 15-20

詳細
抄録
Precast columns using 150MPa concrete were produced, and bond strength of the ceramic tile was investigated. As a result, the following conclusions were obtained. (1) Bond strength of tile in 150 MPa concrete column was higher than that of 60 MPa concrete column. (2) Bond strength of most tiles was high enough compared with a regulated value. (3) It was useful for the improvement of bond strength to paint the acrylic silicon resin on the backside of the tile. (4) The direction of the back foot did not influence bond strength of the tile.