日本建築学会技術報告集
Online ISSN : 1881-8188
Print ISSN : 1341-9463
ISSN-L : 1341-9463
構造
木質断熱複合パネルのせん断耐力性能に及ぼす壁高さの影響に関する実験的研究
梅森 浩宮澤 健二
著者情報
ジャーナル フリー

2009 年 15 巻 30 号 p. 417-420

詳細
抄録
The purpose of this study is to examine the effect of wall height on performance of shear walls. There are a lot of buildings with several heights of walls in wooden house in Japan. It is said that we have to consider influence for shear wall property with low height walls.
However, there seems to be no established theory in this problem.
Therefore we conducted static loading tests of several heights of SIP shear walls. It was found from the result that the strength of low height walls was not reduced. However, we should not overlook the fact that the stiffness of low height walls is higher than standard height walls.
著者関連情報
© 2009 日本建築学会
前の記事 次の記事
feedback