抄録
The structural system composed of reinforced concrete (RC) shear wall and steel frame is presented. A series of experiment conceming the quality control of the high strength concrete and structural behavior of the RC shear wall under seismic load had been performed to develop this system. This system was applied to the actual 25-story building consequently.