日本建築学会技術報告集
Online ISSN : 1881-8188
Print ISSN : 1341-9463
ISSN-L : 1341-9463
構造
パネルゾーンにDFRCCを用いたPCa柱梁接合部の構造性能
佐野 直哉金久保 利之八十島 章細矢 博
著者情報
ジャーナル フリー

2016 年 22 巻 50 号 p. 109-114

詳細
抄録
In this study, the loading test of precast concrete beam-column joints using DFRCC in joint panel is conducted to evaluate effect of preventing crack widening and structural performance of joint panel with DFRCC. The experiment factor is shear reinforcement arrangement in joint panel. The test results are compared with those of conventional concrete specimen with same reinforcement arrangement in previous experiments. From the experiment results, it can be recognized that DFRCC improves the shear performance of precast concrete beam-column joints and confinement effect of DFRCC is the same or higher than that of shear reinforcement.
著者関連情報
© 2016 日本建築学会
前の記事 次の記事