日本建築学会技術報告集
Online ISSN : 1881-8188
Print ISSN : 1341-9463
ISSN-L : 1341-9463
防火
EWECS柱の耐火性能
田口 孝神谷 隆芳賀 裕司鈴木 卓新藤 健太上川 大輔玉置 教司
著者情報
ジャーナル フリー

2018 年 24 巻 56 号 p. 211-216

詳細
抄録
This research is to develop a new wooden hybrid column composed of laminated wood and concrete-steel. This hybrid column is called the EWECS column. EWECS column is made by covering steel with concrete and arranging laminated timber on the outside.
However, this EWECS column uses laminated timber for the outer shell, but its fire resistance performance has not been clarified. Therefore, a fire test was conducted on a full size EWECS column specimen. As a result, it was confirmed that the EWECS column covered in this study has fire resistance performance of 2 hours as a column member.
著者関連情報
© 2018 日本建築学会
前の記事 次の記事
feedback
Top