2019 Volume 25 Issue 60 Pages 715-718
Regarding scattering coefficient that represents acoustic scattering capability of architectural surfaces, a reverberation room method for measuring random-incidence values has been standardized in ISO 17497-1. Besides, an alternative method for measuring normal-incidence values between parallel walls was recently proposed. In this paper, a 1/4-scale-model measurement system integrated for the two measurements is newly developed, where converting the former system into the latter system in a rectangular room with a circular test sample. In order to validate the converted system for normal-incidence scattering coefficient, the test arrangements are examined in experiments, and the measured results are compared with numerical results.
Ethical standards of the publisher (‘Ethical Standards Concerning the Peer Review for the Presentation of Architectural Transactions and Works’)