日本建築学会技術報告集
Online ISSN : 1881-8188
Print ISSN : 1341-9463
ISSN-L : 1341-9463
構造
ヒンジ位置保証型RC梁の力学挙動に主筋の付着除去が与える影響
毎田 悠承益田 一毅佐藤 裕貴坂田 弘安前川 利雄服部 翼
著者情報
ジャーナル フリー

2021 年 27 巻 65 号 p. 231-236

詳細
抄録

In this study, structural tests were performed on the specimens that contained the de-bond of longitudinal rebars at the four corners of the RC beam with a guaranteed hinge position. Through this test, it was confirmed that the de-bond of longitudinal rebars at the four corners of the RC beam does not significantly affect the structural performance of the RC beam member, including the restoring force characteristic and energy dissipation capacity. Moreover, the cracks were concentrated on the hinge-side of the de-bond area, and the number of cracks in the de-bond area was suppressed.

著者関連情報
© 2021, 日本建築学会
前の記事 次の記事
feedback
Top