日本建築学会技術報告集
Online ISSN : 1881-8188
Print ISSN : 1341-9463
ISSN-L : 1341-9463
U字形差し筋を用いたSRC造柱・S造梁接合部の中層建物への適用
藤原 敏夫田中 清佐々木 聡米山 真一朗小林 進寺岡 勝
著者情報
ジャーナル フリー

1999 年 5 巻 7 号 p. 45-50

詳細
抄録
A new type SRC-column to S-Beam joint which composed of U-shaped reinforcing bars and horizontal diagonal diaphragms, is proposed and is applied to a 9-story office building. This joint has been developed to obtain good quality of cast-insited concrete in the joint and good seismic performance of the joint, and also to simplify actual execution at the site. In this paper, outline of the objective building, structural design method, lateral loading test of interior beam and column subassemblage and results of actual execution of the joint are shown.