新設された片側式アーケード内部の気温分布性状
辻原 万規彦平川 真由美田中 稔
著者情報
ジャーナル フリー

2001 年 7 巻 14 号 p. 193-198

詳細
抄録

Thermal environment, especially air temperature distribution, inside the semiclosed arcade located at Nagasaki was investigated on field observations both in summer 2000 and in winter 2001. Air temperature at the height of 1.0 meter in the occupied zone was a little higher than outside air temperature both in summer and in winter. In the daytime of summer, vertical distribution of air temperature showed a slope of high temperature in the upper part and low temperature in the lower part. However, both in the nighttime of summer and winter, vertical distribution of air temperature did not show a slope.