日本建築学会技術報告集
Online ISSN : 1881-8188
Print ISSN : 1341-9463
ISSN-L : 1341-9463
ステンレスシート防水工法の耐風性能解析及び評価に関する研究(材料施工)
飛田 春雄
著者情報
ジャーナル フリー

2003 年 9 巻 17 号 p. 21-24

詳細
抄録
The wind resistivity of waterproofing roof made of stainless steel membrane as well as the effect due to displacement of clips has been analyzed by using an apprximate analytical solution conducted by the author, and an evaluation on the solution was made in comparison with the result of durability test and FEM. As a result, it is verified that the solution can duly be applied. As the peal strength of stainless steel membrane measured by the test is 0.387kgf/mm when the wind pressure is 600kgf/m^2, it is confirmed that this waterproofing roof is sufficiently durable. From the result of this study, the analytical solution can easily be obtained and it hopefully provides a reliable waterproofing roof.
著者関連情報
© 2003 日本建築学会
前の記事 次の記事
feedback