Analytical Sciences
Online ISSN : 1348-2246
Print ISSN : 0910-6340
ISSN-L : 0910-6340
Original Papers
Lead(II)-Selective Electrode Based on Phenyl Disulfide
Abdolkarim ABBASPOURBehnam KHAJEH
著者情報
ジャーナル フリー

2002 年 18 巻 9 号 p. 987-991

詳細
抄録
A PVC membrane electrode for lead ions based on phenyl disulfide as the membrane carrier was developed. The electrode exhibits a good Nernstian slope of 29.3 ± 0.7 mV/decade and a linear range of 2.0 × 10-6 - 1.0 × 10-2 M for Pb(NO3)2. The limit of detection is 1.2 × 10-6 M. It has a response time of 45 s and can be used for at least fifty days without any divergence in potential. The proposed membrane sensor revealed high selectivity for Pb2+ over a wide variety of other metal ions and could be used in the pH range of 3.5 - 6.3. The electrode was used as an indicator electrode in potentiometric titration of lead ions.
著者関連情報
© 2002 by The Japan Society for Analytical Chemistry
前の記事 次の記事
feedback
Top