Analytical Sciences
Online ISSN : 1348-2246
Print ISSN : 0910-6340
ISSN-L : 0910-6340
Original Papers
Simultaneous Determination of Hydroxyanthraquinones in Rhubarb and Experimental Animal Bodies by High-Performance Liquid Chromatography
Mingyu DINGShuaiwu MADelin LIU
著者情報
ジャーナル フリー

2003 年 19 巻 8 号 p. 1163-1165

詳細
抄録

A simple and reliable high-performance liquid chromatographic (HPLC) method was developed for the simultaneous determination of five hydroxyanthraquinones (aloe-emodin, rhein, emodin, chrysophanol, and physcion) in Rhubarb and experimental animal bodies. A Zorbax SB-C18 column (250 mm × 4.6 mm i.d., 5 μm) and a methanol -0.5% acetic acid (85:15, v/v) mobile phase were used for the separation. The detection wavelength of a diode array detector (DAD) was set at 254 nm. Regression equations revealed a linear relationship (R2 > 0.9996) between the mass of hydroxyanthraquinones injected and the peak areas detected by DAD. The detection limits (S/N = 3) ranged from 0.35 ng to 3.13 ng, and the recoveries ranged from 83% to 103% for different hydroxyanthraquinones. This method is simple, sensitive and suitable for the analysis of hydroxyanthraquinones in medicinal materials and pharmacological experiment samples.

著者関連情報
© 2003 by The Japan Society for Analytical Chemistry
前の記事 次の記事
feedback
Top