Analytical Sciences
Online ISSN : 1348-2246
Print ISSN : 0910-6340
ISSN-L : 0910-6340
Original Papers
Detection of Scopolamine Hydrobromide via Surface-enhanced Raman Spectroscopy
Lin BAOXuan-Yu SHAHang ZHAOSi-qin-gao-wa HANWu-Li-Ji HASI
著者情報
ジャーナル フリー

2017 年 33 巻 11 号 p. 1237-1240

詳細
抄録
Surface-enhanced Raman spectroscopy (SERS) was used to measure scopolamine hydrobromide. First, the Raman characteristic peaks of scopolamine hydrobromide were assigned, and the characteristic peaks were determined. The optimal aggregation agent was potassium iodide based on a comparative experimental study. Finally, the SERS spectrum of scopolamine hydrobromide was detected in aqueous solution, and the semi-quantitative analysis and the recovery rate were determined via a linear fitting. The detection limit of scopolamine hydrobromide in aqueous solution was 0.5 μg/mL. From 0 – 10 μg/mL, the curve of the intensity of the Raman characteristic peak of scopolamine hydrobromide at 1002 cm−1 is y = 4017.76 + 642.47x. The correlation coefficient was R2 = 0.983, the recovery was 98.5 – 109.7%, and the relative standard deviation (RSD) was about 5.5%. This method is fast, accurate, non-destructive and simple for the detection of scopolamine hydrobromide.
Fullsize Image
著者関連情報
© 2017 by The Japan Society for Analytical Chemistry