Analytical Sciences
Online ISSN : 1348-2246
Print ISSN : 0910-6340
ISSN-L : 0910-6340
Detection of Chemiluminescent Labeling Compounds by Photographic Method. Preliminary Investigation on 1, 10-Phenanthroline-Hydrogen Peroxide and Luminol-Hydrogen Peroxide Systems
Keihei UENOFumio SAGARAIsao YOSHIDAHiroko ENAMIShigeki ETOHHiroshige MIYAZAKIAkinari SONODAMikihiko SAITO
著者情報
ジャーナル フリー

1988 年 4 巻 5 号 p. 477-480

詳細
抄録

The following two chemiluminescent reaction systems were investigated for the photographic detection of ultra-micro amounts of analyte on an agarose gel plate. 1) Reaction of 1, 10-phenanthroline with hydrogen peroxide, which is catalyzed by copper(II) or osmium(VIII). 2) Reaction of luminol with hydrogen peroxide, which is catalyzed by iron(III) complex. Chemiluminescent light was detected using a high-speed instant photographic film, and amounts as small as 9×10-10mol of 1, 10-phenanthroline or 2×10-18mol of iron complex of tetraphenylporphinetrisulfonic acid were detected by this method.

著者関連情報
© The Japan Society for Analytical Chemistry
前の記事 次の記事
feedback