Analytical Sciences
Online ISSN : 1348-2246
Print ISSN : 0910-6340
ISSN-L : 0910-6340
High-Performance Liquid Chromatographic Determination of Ofloxacin in Serum
Tadashi OHKUBOMasakiyo KUDOKazunobu SUGAWARA
著者情報
ジャーナル フリー

1991 年 7 巻 5 号 p. 741-743

詳細
抄録

A high-performance liquid chromatographic method was developed for the assay of ofloxacin in serum. The serum samples were filtered through a Molcut II membrane filter after partial deproteinization in order to remove proteins. The filtrate was preseparated on a reversed-phase precolumn and introduced onto a reversed-phase analytical column by applying column-switching techniques. Ofloxacin and nalidixic acid as internal standards were detected by absorbance measurements at 300nm. Using this system the concentration of ofloxacin could be determined at a limit of the order of 20ng/ml, with a linear dynamic range of 80-4000ng/ml. This procedure was applied to pharmacokinetic studies of healthy volunteers treated with ofloxacin.

著者関連情報
© The Japan Society for Analytical Chemistry
前の記事 次の記事
feedback
Top