Annals of Nuclear Cardiology
Online ISSN : 2424-1741
Print ISSN : 2189-3926
ISSN-L : 2189-3926
Review Articles
Optimal Protocol of Myocardial Perfusion Imaging for Reduction of Radiation Exposure
Yasuyuki SuzukiNaoya MatsumotoShunichi YodaYasuo AmanoYasuo Okumura
著者情報
ジャーナル フリー HTML

2022 年 8 巻 1 号 p. 109-112

詳細
抄録
The Japanese Circulation Society (JCS) 2021 guideline on radiation safety in cardiology was updated based on the eight best practices for myocardial perfusion single-photon emission computed tomography myocardial perfusion imaging (SPECT-MPI), which was determined by panels of international atomic energy agency (IAEA) nuclear cardiology protocols cross-sectional study (INCAPS). Although the guideline recommends to avoid too much 201Tl or 201Tl/99mTc dual-isotope protocol, the utilization rate of 201Tl for SPECT-MPI in Japan is considerably high compared to other countries. In Japan, protocols using 99mTc should be appropriately promoted based on the guideline to reduce radiation exposure in SPECT-MPI. Among the eight practices, stress-only imaging is considered to be a useful strategy that contributes to a significant reduction in radiation exposure, and hybrid assessment in combination with rest computed tomography (CT)-MPI is one of the practical application methods.
著者関連情報
© The Japanese Society of Nuclear Cardiology 2022
前の記事 次の記事
feedback