アジア・太平洋化学工学会議発表論文要旨集
Asian Pacific Confederation of Chemical Engineers congress program and abstracts
セッションID: 1P-10-008
会議情報

Failure Diagnosis System of Flowmeters with Two Stages Based on Control Limits - Extension for Multiple Failures -
Kazushi IshimotoKouhei KitaharaKazuhiro TakedaYoshifumi Tsuge
著者情報
会議録・要旨集 フリー

詳細
抄録
Failure diagnosis of flowmeters based on control limits has been developed as a method to identify faulty flowmeters, which should be calibrated during a maintenance period, during plant operation. This method is very useful for the diagnosis of flowmeters having faulty errors with magnitudes greater than three times their control limits. However, there is a shortcoming in that the diagnostic results given by this method often miss giving alarms when they should, or give false diagnoses, for faulty errors with magnitudes less than three times their control limits. In this study, the diagnostic results given by this method during plant operation are not adopted in a straightforward manner. Instead, at least one flowmeter is selected and calibrated during a maintenance period, to identify the true value of a flowrate. As a result, the diagnostic accuracy can be improved by performing a second diagnosis using the calibrated values of the flowrates. Furthermore, the performance of the method presented is demonstrated by numerical experiments on a simplified refinery model containing 11 flowmeters.
著者関連情報
© 2004 The Society of Chemical Engineers, Japan
前の記事 次の記事
feedback
Top