Annals of Thoracic and Cardiovascular Surgery
Online ISSN : 2186-1005
Print ISSN : 1341-1098
ISSN-L : 1341-1098
Original Articles
Long-Term Results of Modified Bentall Procedure Using Flanged Composite Aortic Prosthesis
Kiyoshi TamuraHirokuni AraiSatoru KawaguchiSatoru MakitaNaoto MiyagiTaiju WatanabeTatsuki Fujiwara
著者情報
ジャーナル フリー

2013 年 19 巻 2 号 p. 126-130

詳細
抄録

Purpose: We have been using the flanged composite aortic prosthesis and Carrel button technique to re-attach the coronary ostia in aortic root replacement procedures at our institution over the last twenty five years. Our objective was to evaluate the long-term results of aortic root replacement with this technique.
Methods: A total of 73 patients from January 1984 to August 2010 were included in this study. The median age was 52.7 ± 14.4 years (range 28–80 years). There were 48 male and 25 female patients. 44 patients (60.3%) had annuloaortic ectasia, and 15 patients (20.5%) had acute type A aortic dissection. Marfan syndrome was recognized in 12 patients (16.5%).
Results: The early mortality rate was 5.5% (n = 4). Causes of death were multiple organ failures in two patients and sepsis in another two patients. The actuarial survival rate was 84.2% at 5 years, 64.3% at 15 years and 51.9% at 25 years. Only one patient with aortitis needed a reoperation because of coronary pseudoaneurysm after 23 years from the previous operation.
Conclusion: This modified Bentall procedure is reliable and safe, with superior long-term survival and a low rate of aortic reoperation.

著者関連情報
© 2013 The Editorial Committee of Annals of Thoracic and Cardiovascular Surgery

This article is licensed under a Creative Commons [Attribution-NonCommercial-NoDerivatives 4.0 International] license.
https://creativecommons.org/licenses/by-nc-nd/4.0/