Annals of Thoracic and Cardiovascular Surgery
Online ISSN : 2186-1005
Print ISSN : 1341-1098
ISSN-L : 1341-1098
Case Reports
Pseudo Systolic Anterior Motion: Potential for Severe Mitral Regurgitation after Aortic Valve Replacement
Hirofumi KasaharaYoshito InoueSatoru SuzukiIchiro Hayashi
Author information
JOURNAL FREE ACCESS

2014 Volume 20 Issue 4 Pages 329-331

Details
Abstract
A 68-year-old man with severe aortic stenosis (AS) and marked left ventricular hypertrophy (LVH), underwent aortic valve replacement (AVR). Preoperative echocardiography demonstrated contact between the anterior mitral leaflet and the interventricular septum during diastole without mitral regurgitation (MR), i. e., “pseudo systolic anterior motion (SAM). " After a mechanical prosthesis had been implanted, severe mitral regurgitation MR and pulmonary hypertension occurred due to “true" SAM of the mitral valve. Despite intensive management, it was difficult to control MR in the acute phase.In the chronic phase, echocardiography revealed the resolution of both SAM and MR. It is suggested that the dramatic reduction of afterload after alleviation of valvular stenosis by prosthetic replacement and increased flow velocity in the left ventricular outflow tract (LVOT) caused SAM with MR. The risk of SAM after AVR should be considered in AS patients with marked LVH, especially in the presence of “pseudo SAM. "
Content from these authors
© 2014 The Editorial Committee of Annals of Thoracic and Cardiovascular Surgery

This article is licensed under a Creative Commons [Attribution-NonCommercial-NoDerivatives 4.0 International] license.
https://creativecommons.org/licenses/by-nc-nd/4.0/
Previous article Next article
feedback
Top