Annals of Thoracic and Cardiovascular Surgery
Online ISSN : 2186-1005
Print ISSN : 1341-1098
ISSN-L : 1341-1098
Case Reports
Prevention of Kinked Stent Graft Limb Due to Severe Angulated Proximal Neck during Endovascular Repair for Abdominal Aortic Aneurysm
Pyung Chun OhMinsu KimEak Kyun ShinWoong Chol Kang
Author information
JOURNAL OPEN ACCESS

2018 Volume 24 Issue 2 Pages 106-109

Details
Abstract

Although the technology of endovascular aortic repair (EVAR) for abdominal aortic aneurysm (AAA) is evolving that make it appealing for challenging anatomy, proximal aortic neck morphology, especially severe angulation, is still one of the most determinants for a successful procedure. We describe a patient of AAA with severely angulated proximal neck, in whom kinked stent graft limb occurred against severe angulation of proximal neck. Then, we suggested how to prevent this complication in the second patient. Our case demonstrated the stent graft limb could be kinked by severe aortic neck angulation, making it challenging. However, the kinked stent graft limb could be prevented by deploying stent graft limbs below the most severely angulated aortic neck intentionally.

Content from these authors
© 2018 The Editorial Committee of Annals of Thoracic and Cardiovascular Surgery

This article is licensed under a Creative Commons [Attribution-NonCommercial-NoDerivatives 4.0 International] license.
https://creativecommons.org/licenses/by-nc-nd/4.0/
Previous article Next article
feedback
Top