Aorto–right Ventricular Fistula: A Complication of Aortic Valve Replacement
Mohammad Q. NajibDaniel NgKaryne L. VinalesHari P. Chaliki
Author information
JOURNAL OPEN ACCESS Advance online publication

Article ID: cr.11.01671

Details
Abstract
The occurrence of aorto–right ventricular (aorto-RV) fistula after prosthetic aortic valve replacement is rare. Transthoracic echocardiography (TTE) with color-flow Doppler, transesophageal echocardiography (TEE), or both may be required for diagnosis. A 42-year-old woman sought care for palpitations and dyspnea due to atrial flutter 2 weeks after prosthetic aortic valve replacement and graft replacement of the ascending aorta. TTE and TEE revealed left-to-right shunt due to aorto-RV fistula.