Annals of Thoracic and Cardiovascular Surgery
Online ISSN : 2186-1005
Print ISSN : 1341-1098
ISSN-L : 1341-1098

この記事には本公開記事があります。本公開記事を参照してください。
引用する場合も本公開記事を引用してください。

Prevention of Kinked Stent Graft Limb Due to Severe Angulated Proximal Neck during Endovascular Repair for Abdominal Aortic Aneurysm
Pyung Chun OhMinsu KimEak Kyun ShinWoong Chol Kang
著者情報
キーワード: AAA, EVAR, kinked stent graft limb
ジャーナル オープンアクセス 早期公開

論文ID: cr.17-00072

この記事には本公開記事があります。
詳細
抄録

Although the technology of endovascular aortic repair (EVAR) for abdominal aortic aneurysm (AAA) is evolving that make it appealing for challenging anatomy, proximal aortic neck morphology, especially severe angulation, is still one of the most determinants for a successful procedure. We describe a patient of AAA with severely angulated proximal neck, in whom kinked stent graft limb occurred against severe angulation of proximal neck. Then, we suggested how to prevent this complication in the second patient. Our case demonstrated the stent graft limb could be kinked by severe aortic neck angulation, making it challenging. However, the kinked stent graft limb could be prevented by deploying stent graft limbs below the most severely angulated aortic neck intentionally.

著者関連情報
© 2017 The Editorial Committee of Annals of Thoracic and Cardiovascular Surgery

This article is licensed under a Creative Commons [Attribution-NonCommercial-NoDerivatives 4.0 International] license.
https://creativecommons.org/licenses/by-nc-nd/4.0/