抄録
It is often desirable to obtain gene libraries with the greatest possible number of variants. We tested two different methods for desalting the products of library ligation reactions (silica-based microcolumns and drop dialysis), and examined their effects on final library size. For both intramolecular and intermolecular ligation, desalting by drop dialysis yielded approximately 3–5 times more transformants than microcolumn purification.