Bioscience, Biotechnology, and Biochemistry
Online ISSN : 1347-6947
Print ISSN : 0916-8451

This article has now been updated. Please use the final version.

Chemiluminescent Enzyme Immunoassay for Measuring Leptin
Satoshi SEKIGUCHIHideki KOHNOKiyoshi YASUKAWAKuniyo INOUYE
Author information
JOURNAL FREE ACCESS Advance online publication

Article ID: 100885

Details
Abstract
Leptin is one of the representative adipocyte-derived protein hormones. Measuring the serum leptin concentration gives an important index for preventing and treating diabetes mellitus and other diseases. We constructed in this study a chemiluminescent enzyme immunoassay (CLEIA) for measuring leptin by using the anti-leptin polyclonal antibody and alkaline phosphatase (ALP). The method applies the IgG-conjugated ferrite particle to capture leptin in a sample and the ALP-conjugated Fab fragment to detect the captured leptin. We tested Block ace, CE510, and bovine serum albumin (BSA) for their abilities to block non-specific binding of ALP-conjugated anti-leptin Fab to the ferrite particle and found BSA to be the most effective. The measurable range with this ELISA for leptin was 0.1–1.0 pg/mL of leptin and the detection limit (blank+2SD) was 0.1 pg/mL of leptin. These results demonstrate sufficient sensitivity with our system to measure the serum leptin concentration and its clinical usefulness. The results also suggest that a sensitive enzyme immunoassay can be constructed by using only one polyclonal antibody.
Content from these authors

This article cannot obtain the latest cited-by information.

© 2011 by Japan Society for Bioscience, Biotechnology, and Agrochemistry
feedback
Top