Biological and Pharmaceutical Bulletin
Online ISSN : 1347-5215
Print ISSN : 0918-6158
ISSN-L : 0918-6158
A Rapid Assay of Granisetron in Biological Fluids from Cancer Patients
Ikuo WADAMichiko SATOHTakeo TAKEDATakehito NAKABAYASHITakanori HONMAHiroshi SAITOHMasahiko TAKADAKazuyuki HIRANO
Author information
JOURNAL FREE ACCESS

1998 Volume 21 Issue 5 Pages 535-537

Details
Abstract

A convenient high-performance liquid chromatography (HPLC) was developed for the rapid assay of granisetron (GRN) in biological fluids, such as serum, urine, and pleural effusion, from cancer patients. Extrelut<[○!R]>-1 was used for the solid-phase extraction. HPLC was carried out using a LiChroCART<[○!R]> cartridge column packed with Lichrospher 100 CN and a mobile phase consisting of 0.1 M acetate buffer (pH 3.5) and acetonitrile (7 : 3). A fluorescence detector of 290 nm for excitation and 365 nm for emission was used. The standard curve was linear over the range of 2 to 100 ng/ml of GRN. Assay precision, expressed as a coefficient of variation (C.V.), was in the range of 0.9-5.4% in the within-day assay and 2.5-6.9% in the between-day assay, respectively. GRN was well separated on the HPLC chromatogram from drugs such as etoposide, metclopramide, ondansetron, and domperidone which are often used together with GRN. It was suggested that the present method is useful for the rapid monitoring of GRN in the serum, urine, and pleural effusion of patients undergoing cancer chemotherapy.

Content from these authors
© The Pharmaceutical Society of Japan
Previous article Next article
feedback