Circulation Journal
Online ISSN : 1347-4820
Print ISSN : 1346-9843
ISSN-L : 1346-9843
Clinical Investigation
One-Year Clinical Outcomes of Dialysis Patients After Implantation With Sirolimus-Eluting Coronary Stents
Takenori OkadaYasuhiko HayashiMamoru ToyofukuMichinori ImazuMasaya OtsukaTadamichi SakumaHironori UedaHideya YamamotoNobuoki Kohno
Author information
JOURNAL FREE ACCESS

2008 Volume 72 Issue 9 Pages 1430-1435

Details
Abstract

Background The efficacy of sirolimus-eluting stents (SESs) has not been established in dialysis patients. Methods and Results This study was a non-randomized observational single-center registry in a community hospital: data for 80 consecutive dialysis patients who underwent percutaneous coronary intervention (PCI) with SES were compared with those of a historical group of consecutive 124 dialysis patients treated with bare-metal stents (BMS). After 1 year, the cumulative incidence of major adverse cardiac events (MACE), comprising cardiac death, nonfatal myocardial infarction, stent thrombosis, or target lesion revascularization (TLR), was 25.2% in the SES group and 38.2% in the BMS group (p=0.048). In multivariate analysis, use of SES remained an independent predictor of MACE at 1 year after PCI (risk ratio 0.70, 95% confidence interval 0.52-0.93, p=0.015). Rates of TLR were 21.7% in the SES group and 30.9% in the BMS group and (p=0.15). Subgroup analysis showed that use of SES was effective in patients with small vessels, non-diabetic patients, and patients without highly calcified lesions. Conclusions In dialysis patients, the implantation of SES was moderately effective in reducing MACE at 1 year after PCI as compared with BMS. However, the TLR rate at 1 year was relatively higher than previously reported. (Circ J 2008; 72: 1430 - 1435)

Content from these authors
© 2008 THE JAPANESE CIRCULATION SOCIETY
Previous article Next article
feedback
Top