Circulation Journal
Online ISSN : 1347-4820
Print ISSN : 1346-9843
ISSN-L : 1346-9843

This article has now been updated. Please use the final version.

Two-Year Outcomes of Primary Prophylactic Use of Defibrillators for Ischemic and Non-Ischemic Cardiomyopathy ― Propensity Score-Matched Analysis From the Nippon Storm Study ―
Yusuke Kondo Takashi NodaYukiko TakanashiShingo SasakiYasunori SatoTakashi NittaYoshifusa AizwaTohru OheTakashi Kurita
Author information
JOURNAL OPEN ACCESS FULL-TEXT HTML Advance online publication

Article ID: CJ-23-0613

Details
Abstract

Background: In 2016, the DANISH study reported negative results regarding the efficacy of implantable cardioverter-defibrillators (ICDs) in patients with non-ischemic cardiomyopathy (NICM) and reduced left ventricular ejection fraction (LVEF). In this study we determined the efficacy of using ICDs for primary prophylaxis in patients with NICM.

Methods and Results: We selected 1,274 patients with underlying cardiac disease who were enrolled in the Nippon Storm Study. We analyzed the data of 451 patients with LVEF ≤35% due to NICM or ischemic cardiomyopathy (ICM) who underwent ICD implantation for primary prophylaxis (men, 78%; age, 65±12 years; LVEF, 25±6.4%; cardiac resynchronization therapy, 73%; ICM, 33%). After propensity score matching, we compared the baseline covariates between groups: NICM (132 patients) and ICM (132 patients). The 2-year appropriate ICD therapy risks were 27.7% and 12.2% in the NICM and ICM groups, respectively (hazard ratio, 0.390 [95% confidence interval, 0.218–0.701]; P=0.002).

Conclusions: This subanalysis of propensity score-matched patients from the Nippon Storm Study revealed that the risk of appropriate ICD therapy was significantly higher in patients with NICM than in those with ICM.

Content from these authors
© 2023, THE JAPANESE CIRCULATION SOCIETY