2014 Volume 62 Issue 12 Pages 1225-1230
This study reports the results of applying the time–temperature superposition principle (TTSP) to the prediction of color changes in liquid formulations. A sample solution consisting of L-tryptophan and glucose was used as the model liquid formulation for the Maillard reaction. After accelerated aging treatment at elevated temperatures, the Commission Internationale de l’Eclairage (CIE) LAB color parameters (a*, b*, L*, and E*ab) of the sample solution were measured using a spectrophotometer. The TTSP was then applied to a kinetic analysis of the color changes. The calculated values of the apparent activation energy of a*, b*, L*, and ΔE*ab were 105.2, 109.8, 91.6, and 103.7 kJ/mol, respectively. The predicted values of the color parameters at 40°C were calculated using Arrhenius plots for each of the color parameters. A comparison of the relationships between the experimental and predicted values of each color parameter revealed the coefficients of determination for a*, b*, L*, and ΔE*ab to be 0.961, 0.979, 0.960, and 0.979, respectively. All the R2 values were sufficiently high, and these results suggested that the prediction was highly reliable. Kinetic analysis using the TTSP was successfully applied to calculating the apparent activation energy and to predicting the color changes at any temperature or duration.
The color of pharmaceutical products is an important quality attribute. Color changes in pharmaceutical products are often indicative of either poor-quality production or product instability.1,2) Color measurement is one type of quality assurance test that should be performed during the development of pharmaceutical products.3) Techniques for preventing changes in the color of the product are often used. For example, the use of antioxidant agents and color agents is a common solution for stabilizing the color appearance of products.4) In some cases, however, color changes occur very slowly over time. If a commercialized product exhibits a color change before it can be sold, the product should be recalled. Therefore, a method for predicting color changes is important for the development of products within a short time period and for determining the shelf-life of a product. In the food industry, methods for predicting color changes over time have been thoroughly studied as an index of quality. Several reports have discussed the kinetics of color changes in food products, such as broccoli juice,5) apple puree,6) and green asparagus.7) In the pharmaceutical industry, kinetic analyses of changes in the color of solid dosage forms have been reported with a variety of purpose, including the prediction of discoloration,8) evaluations of the coloration of photosensitive solid drugs,9) elucidation of the discoloration kinetics of uncoated white tablets,10) examinations of coloration during long-term stability tests,11) and the examination of color stabilization through the use of film coating.12) On the other hand, few methods for predicting color changes in liquid formulations have been developed. Previous studies of liquid formulations have concentrated on the color changes of a single component, such as ascorbic acid, thiamin hydrochloride, reserpine, cefazolin sodium, or ceftizoxime sodium.13,14) In general, the color of a liquid formulation can undergo changes more easily than a solid formulation because of hydrolysis reactions, oxidation reactions, and other chemical reactions of active ingredients and other additives. Seki et al. reported a method of predicting color changes using a Weibull probability plotting paper and data on the reduction in percent transmittance at 430 nm.14) Kitamura et al. calculated the reaction order of color changes using Matsuda’s equation9) and data on the total color difference (ΔE).13) However, these reports did not describe the property of color changes and required complicated calculations based on reaction models.
In this study, a simple model system based on the Maillard reaction of a liquid formulation composed of an amino acid and a reducing sugar was used to develop a method for predicting color changes in liquid formulations. The Maillard reaction is one of the most common non-enzymatic browning reactions in liquid formulation. During this reaction, hundreds of different compounds are created.15) Since the causal compounds of the browning reaction are difficult to specify, the change in appearance was monitored as one of the physical properties. Such color studies are traditionally performed using Commission Internationale de l’Eclairage (CIE) LAB color parameters (a*, b*, L*, and ΔE*ab) to measure color differences in a quantitative manner.16) The CIELAB color parameters can describe all the colors visible to the human eye. In principle, the application of numerous kinetic models should be attempted, and the best-fit model for each color parameter should be defined. However, the search process for identifying the most appropriate kinetic model is time-consuming, and best-hit models can be difficult to identify. In the present study, the time–temperature superposition principle (TTSP) was applied to the data, instead of the conventional use of complicated kinetic models. The superiority and limitations of the TTSP method are discussed from the perspective of solving real-life problems.
The liquid formulation used for the Maillard reaction model was composed of glucose as the reducing sugar (San-ei Sucrochemical Co., Ltd., Japan) and L-tryptophan as the amino acid (KENEI Pharmaceutical Co., Ltd., Japan). The following compounds that were used to prepare a citrate buffer solution were obtained commercially: citric acid (Iwata Chemical Co., Ltd., Japan), sodium citrate (SATUMA KAKO Co., Ltd., Japan), and sodium benzoate (Aioi ChemiScience Co., Ltd., Japan). The sample solution was prepared by dissolving glucose and L-tryptophan in a solution (25 mM citrate buffer, 4.2 mM sodium benzoate) to yield final concentrations of 10 mM L-tryptophan and 300 mM glucose, with a pH of 6.0. A 15-mL glass container (Maruemu Co., Ltd., Japan) was used to store the 15 mL liquid formulation at various temperatures.
Sample TreatmentThe sample solutions were stored in a stability chamber (Nagano Science Co., Ltd., Japan) at 40°C, 50°C, 60°C, 65°C, 70°C, 75°C, and 80°C. Table 1 shows the duration of storage at each treatment temperature.
Temperature | Storage time (h) | ||||||||
---|---|---|---|---|---|---|---|---|---|
80°C | 4 | 10 | 16 | 24 | 30 | 38 | 44 | 50 | 56 |
75°C | 6 | 16 | 24 | 34 | 38 | 46 | 55 | 62 | 70 |
70°C | 10 | 24 | 34 | 48 | 58 | 72 | 84 | 106 | 152 |
65°C | 24 | 48 | 72 | 96 | 144 | 192 | 240 | 288 | 336 |
60°C | 31 | 55 | 96 | 168 | 240 | 288 | 336 | 384 | 432 |
50°C | 72 | 144 | 216 | 288 | 360 | 432 | 504 | 576 | 648 |
40°Ca) | 336 | 672 | 1344 | 1680 | 2016 | 2688 | 3360 | 4032 | — |
a) The results obtained at 40°C were used for comparison with the predicted data.
The color parameters were measured using a spectrophotometer (CM-3500d; KONICA MINOLTA, INC., Japan) under a D65 light source and an observed angle of 10°. The CIELAB color parameters (a*, b*, L*, and ΔE*ab) authorized in JIS Z872916) and JIS Z873017) were used to express the color changes. Figure 1 shows the CIELAB color space diagram. L* expresses the lightness from white (100) to black (0). Both a* and b* express the hue and the chromaticness, i.e., a* is green (−a*) –red (+a*) axis, and b* is blue (−b*) –yellow (+b*) axis. The differences in the parameters (Δa*, Δb*, and ΔL*) and the total color differences (ΔE*ab) were calculated using the following equations16,17):
![]() | (1) |
![]() | (2) |
![]() | (3) |
![]() | (4) |
A kinetic analysis is a useful method of predicting color changes over time. The data analysis was performed using Microsoft Excel 2010. The Arrhenius equation is a fundamental approach to performing a kinetic analysis of chemical reactions18):
![]() | (5) |
![]() | (6) |
![]() | (7) |
![]() | (8) |
The experimental results showing the appearance of the sample solution at 80°C are presented in Fig. 2. The color of the sample solution turned from colorless to dark brown with an increasing storage time in the stability chamber. The same color changes were observed in the other samples under all the storage conditions. The time courses of the color parameters (a*, b*, L*, and ΔE*ab) at various storage temperatures are shown in Fig. 3. The shapes of the time courses in the graph differed for each of the color parameters. The a* values (upper left) immediately decreased and then increased thereafter. The shape of time course for a* at 50°C seems to be not the same as those at the other temperatures (60–80°C). It might be caused by relatively short reaction time and slow reaction rate of color change at 50°C. This complicated behavior indicated that at first the color of the sample solution turned green, then the direction of the reaction changed and the color became red. The b* values (upper right) monotonically increased at all the temperatures. This finding indicated that the color of the sample solution steadily became more yellow. A steady decrease in the L* values (lower left) indicated that the color of the sample solution darkened. The total color change (ΔE*ab) was defined as the Euclidean distance in three dimensions composed of the Δa*, Δb*, and ΔL*values. At all the temperatures, the ΔE*ab values (lower right) increased with an increase in the storage time, and the appearance turned from colorless to brown.
Each datum represents the mean of three determinations.
To evaluate the apparent activation energy, the TTSP was adopted. A temperature of 65°C was selected as Tref. Polynomial regression equations were applied to the values of a*, b*, L*, and ΔE*ab at 65°C expressed as a function of time. The regression order providing the best fit was selected based on the one with the lowest AIC value. Table 2 shows the AIC for each parameter. As a result, the third-order was selected for the b* and ΔE*ab values, while the fourth order was selected for the a* and L* values. The value of aT was calculated so as to minimize the RMSE of the difference between the measured color parameters and the regressions curves at 65°C. Figure. 4 shows the best-fit regression curve of each of the color parameters at 65°C and the value of aT at various temperatures. The Arrhenius plots of the ΔE*ab values using the aT value and its linear regression line are shown in Fig. 5 as an example. Table 3 shows the Ea and R2 values for each parameter. For each of the color parameters, the R2 values for the Arrhenius plot were sufficiently high; therefore, the Ea values were accurately calculated. As the results calculated from Eq. 8, the Ea value of ΔE*ab was 103.7 (kJ/mol). In the same way, the Ea values of a*, b*, and L* were 105.2, 109.8, and 91.6 (kJ/mol), respectively. In this sample solution, the same chemical reactions might occur at all temperatures, since the temperature dependence of the shift factor was linear. The coloring of the sample solution is based on the chemical species and concentration of compounds produced by chemical reactions. For the same reason the change of color parameters is also dependent on the chemical species and concentration of compounds. As consequence, it was thought that the Ea values had been estimated from color parameters such as a*, b* and L*.
Second-order | Third-order | Fourth-order | Fifth-order | |
---|---|---|---|---|
a* | 212.1 | 209.8 | 154.7 | 171.0 |
b* | 262.4 | 231.6 | 236.3 | 256.7 |
L* | 285.9 | 234.0 | 136.0 | 222.6 |
ΔE*ab | 280.3 | 179.8 | 197.6 | 273.3 |
Each datum represents the mean of three determinations.
Ea (kJ/mol) | R2 | |
---|---|---|
a* | 105.2 | 0.997 |
b* | 109.8 | 0.999 |
L* | 91.6 | 0.997 |
ΔE*ab | 103.7 | 0.999 |
To predict the color changes at 40°C, the shift factor aT at 40°C was calculated from the Arrhenius plots for each of the color parameters. The color parameters for 4032 h of storage at 40°C were evaluated, and the relationships between the experimental and predicted values of the color parameters were investigated. These results are shown in Fig. 6. The coefficients of determination (R2) between the experimental and predicted a*, b*, L*, and ΔE*ab values were 0.961, 0.979, 0.960, and 0.979, respectively. All the R2 values were sufficiently high (R2>0.96), suggesting a highly reliable prediction. However, the prediction ability of a* and L* is somewhat poor compared with that of b* and ΔE*ab. It is likely that the signal-to-noise ratio is one of the primacy causes of lowering the prediction ability of a* and L*.
Using this method, the accuracy of prediction is influenced by the selection of the polynomial regression equation for the master curve and the calculation of the shift factor. We optimized the order of the polynomial regression equation for the master curve based on the AIC. Using the AIC, the shift factor was adequately calculated because the RMSE values between the master curves and the experimental data were minimized for all the color parameters. The consideration of experimental errors, such as sample variability, temperature control in the stability chamber, and the spectrophotometer measurements, are also important for maximizing the accuracy.
According to the above results, color changes associated with Maillard browning in a liquid formulation can be successfully evaluated using a kinetic analysis incorporating the TTSP. This prediction method using TTSP is simple and can easily be applied to extrapolate accelerated aging data to any desired temperature. However, the color prediction using TTSP does have some limitations. The different behaviors of different color parameters are likely caused by the chemical reactions of each component. The CIELAB color parameters are reflected by many chemical reactions. To understand the details of the chemical reactions, quantitative analysis at different wavelength spectra and the identification of the chemical components would be needed. When the behavior of color changes varies with temperature, the time courses for the color parameters will exhibit different shapes. Furthermore, the TTSP can only be applied to thermal aging. In the case of oxidation, the color changes are mainly influenced by the concentration of oxygen. Nevertheless, the TTSP has superior merits beyond a conventional kinetic analysis. No matter how complicated, the process underlying the reaction models does not need to be identified for the application of the TTSP.
The Maillard reaction of a model liquid formulation after accelerated aging treatment at elevated temperatures was measured using the CIELAB color parameters (a*, b*, L*, and ΔE*ab). The a* values initially decreased and then increased. The L* values steadily decreased, while the b* and ΔE*ab values increased linearly throughout the storage period. A kinetic analysis using the TTSP was successfully applied to calculate the apparent activation energy and to predict color changes at any temperature and duration. To predict color changes, the CIELAB parameters are useful for quantifying color changes after long periods of aging at ambient conditions, since the CIELAB parameters can be used to describe all colors visible to the human eye. Therefore, the simultaneous evaluation of these three color parameters is preferable. Even though the time courses for each of the color parameters exhibited a different behavior, the TTSP was easily applied to all the color parameters. The TTSP is helpful as a novel method of predicting color changes, compared with conventional techniques using complicated reaction models.