Chemical and Pharmaceutical Bulletin
Online ISSN : 1347-5223
Print ISSN : 0009-2363
ISSN-L : 0009-2363
Notes
Monitoring Analysis of Perfluoroalkyl Substances and F-53B in Bottled Water, Tea and Juice Samples by LC-MS/MS
Yuki IgarashiMiki TakahashiTomoaki TsutsumiKoichi InoueHiroshi Akiyama
著者情報
ジャーナル フリー HTML
電子付録

2021 年 69 巻 3 号 p. 286-290

詳細
抄録

Monitoring analysis of 14 per- and polyfluoroalkyl substances (PFAS), 9-chlorohexadecafluoro-3-oxanonane-1-sulfonate (F-53B) and dodecafluoro-3H-4,8-dioxanonanoate (ADONA) in bottled drinking water, tea and juice samples was performed using LC coupled with tandem mass spectrometry (LC-MS/MS) and solid-phase extraction (SPE). In the electrospray negative ion mode, the limit of detection and limit of quantification (LOQ) values were 0.1 to 0.8 ng/mL and 0.2 to 1.6 ng/mL, respectively. The calibration curves were linear from LOQ to 50 ng/mL (r2 > 0.999). The SPE procedure (Presep PFC-II) was utilized for sample preparation and recovery rates for three standards (35, 70 and 140 ng/L) were 80.4–118.8% with relative standard deviation (RSD) ≤ 0.6%. Using the developed method, various samples (n = 54) from Japanese markets were investigated for PFAS and F-53B contamination, and values below the LOQ were observed. It is concluded that for monitoring products in the Japanese market, our method represents a significant improvement over complex techniques for the quantification of PFAS and related compounds from various foods.

Fullsize Image
著者関連情報
© 2021 The Pharmaceutical Society of Japan
前の記事 次の記事
feedback
Top