Chemical and Pharmaceutical Bulletin
Online ISSN : 1347-5223
Print ISSN : 0009-2363
ISSN-L : 0009-2363
Quantitative Analysis of the Isomers of Hydroxyphenylalanine by Ion-exchange Chromatography
SUSUMU ISHIMITSUSADAKI FUJIMOTOAKIRA OHARA
Author information
JOURNAL FREE ACCESS

1976 Volume 24 Issue 10 Pages 2556-2558

Details
Abstract
A method for separatory determination of the isomers of hydroxyphenylalanine by liquid chromatography was established. The chromatographic conditions were as follows : Column, glass column (0.9×50cm) packed with Hitachi #2612 ion-exchange resin ; mobile phase, 0.2M citrate buffer (pH 2.80) and 0.2M citrate buffer (pH 3.90) ; flow rate, 1.0 ml/min ; temperature change from 30°to 55°at 3.25 hr ; buffer change at 1.5 hr ; detector, ultraviolet and visible detector.