コンクリート工学論文集
Online ISSN : 2186-2745
Print ISSN : 1340-4733
ISSN-L : 1340-4733
炭素繊維補強の防火性能について
斎藤 秀人池谷 純一
著者情報
ジャーナル フリー

2000 年 11 巻 3 号 p. 63-70

詳細
抄録
Carbon fibers are one of the most effective materials for seismic strengthening. However fire endurance of strengthening with carbon fiber reinforced plastics (CFRP) should be taken into account because of its combustibility. This paper describes the several tests in accordance with methods of Japanese Industrial Standard; tensile strength tests of CFRP exposed with elevated temperature, residual tensile strength tests of CFRP exposed with elevated temperature, quasi-noncombustibility tests of CFRP and fire resistance tests of wall, column, column with wing walls and T-shaped beam specimens strengthened with CFRP. As the results of the tests, tensile strength of CFRP at 40 °C decreased to approximately 40-50 % of normal tensile strength. Residual tensile strength of CFRP had heated up to 200 °C were two-thirds of normal tensile strength. CFRP covered with a plaster board had quasinoncombustibility. For fire resistance, reinforced concrete members strengthened with CFRP maintained their functions during 2 hours. Reinforced concrete walls or slabs with CFRP penetrations maintained their functions during 2 hours.
著者関連情報
© 公益社団法人 日本コンクリート工学会
前の記事 次の記事
feedback