Corrosion Behavior of Pure Titanium and Titanium Alloys in Various Concentrations of Acidulated Phosphate Fluoride (APF) Solutions
Yoshinari MATONOMasaharu NAKAGAWAShigeki MATSUYAKunio ISHIKAWAYoshihiro TERADA
Author information
JOURNAL FREE ACCESS

2006 Volume 25 Issue 1 Pages 104-112

Details
Abstract
The corrosion behaviors of Ti, Ti-6Al-7Nb and Ti-6Al-4V alloys, and an experimentally produced Ti-0.5Pt alloy in 0.05% to 2.0% concentrations of Acidulated Phosphate Fluoride (APF) solutions (corresponding to 226 to 9,050 ppm fluoride at pH 3.5 or 3.6) were examined. While the corrosion of Ti, Ti-6Al-7Nb and Ti-6Al-4V alloys might occur easily even in a diluted 0.05% APF solution, dissolution of Ti from the Ti-0.5Pt alloy was observed only in test solutions with APF concentration exceeding 0.2%. When Ti-6Al-7Nb and Ti-6Al-4V alloys were immersed in 2.0% APF solution, their surfaces were entirely covered by compact corrosion products of Na3TiF6 due to severe corrosion. As a result, Ti dissolution was prevented and the amount of Ti dissolved decreased. However, since Ti was covered by porous, large-sized corrosion products of Na3TiF6 and that Ti-0.5Pt alloy was not covered with any corrosion product, the amount of Ti dissolved increased in the 2.0% APF solution.