The Effect of Bonding System and Composite Type on Adaptation of Different C-factor Restoration
Nipaporn WATTANAWONGPITAKTakako YOSHIKAWAMichael F. BURROWJunji TAGAMI
著者情報
キーワード: C-factor, Bonding system, Adaptation
ジャーナル フリー

2006 年 25 巻 1 号 p. 45-50

詳細
抄録
This study evaluated the effect of two adhesive systems and four resin-based composites on the marginal sealing and cavity wall adaptation of restorations with different C-factors. Cylindrical cavities, 1 mm deep and 3 mm in diameter (C-factor=2.3) or 2 mm in diameter (C-factor=3) , were prepared on superficial bovine dentin surfaces. The teeth were restored with Clearfil SE Bond or Single Bond adhesive system followed by hybrid (Photo Clearfil Bright or Z100) or flowable (Filtek Flow or Estelite LV) resin composite. After thermocycling, a dye penetration test was carried out to evaluate the degree of marginal leakage and cavity-wall gap formation. Cavity-wall gap formation increased when the C-factor increased from 2.3 to 3, except for Estelite LV resin composite. In terms of marginal sealing, Clearfil SE Bond showed better performance than Single Bond. When using Clearfil SE Bond, flowable composites improved resin composite adaptation to the cavity wall compared with hybrid composites.
著者関連情報
© 2006 The Japanese Society for Dental Materials and Devices