Dental Materials Journal
Online ISSN : 1881-1361
Print ISSN : 0287-4547
ISSN-L : 0287-4547
Original papers
Machining Accuracy of Crowns by CAD/CAM System Using TCP/IP: Influence of Restorative Material and Scanning Condition
Sachiko TOMITAAkiyoshi SHIN-YAHarunori GOMIAkikazu SHIN-YADaiichiro YOKOYAMA
Author information
JOURNAL FREE ACCESS

2007 Volume 26 Issue 4 Pages 549-560

Details
Abstract

The purpose of this study was to determine the optimal condition for fabricating accurate crowns efficiently using an internet-based CAD/CAM system. The influences of three different CAD/CAM restorative materials (titanium, porcelain, and composite resin) and three different step-over scanning distances (0.01 mm, 0.11 mm, and 0.21 mm) were evaluated, and their interactive effects were carefully examined.
Several points on the inner and outer surfaces of machined crowns—as well as height—were measured. These measurements were then compared with the original models, from which machining accuracy was obtained. At all measuring points, the inner surface of all crowns was machined larger than the die model, whereas the cervical area of porcelain crown was machined smaller than the crown model. Results of this study revealed that a step-over distance of 0.11 mm was an optimal scanning condition, taking into consideration the interactive effects of scanning time required, data volume, and machining accuracy.

Content from these authors
© 2007 The Japanese Society for Dental Materials and Devices
Previous article Next article
feedback
Top