A New Method for Denture Identification
Fumi TAKAHASHIToshiaki KOJIOsami MORITA
Author information
JOURNAL FREE ACCESS

2008 Volume 27 Issue 2 Pages 278-283

Details
Abstract
Three denture marking methods were performed on specimen plates which were prepared using a heat-cured acrylic resin. The first method (LA) was to place a label into a suitable space on the specimen, and then cover it with autopolymerizing acrylic resin. The second method (DA) was to print the mark directly on the specimen, and then cover it with autopolymerizing acrylic resin. The third method (DB) was to print the mark directly on the specimen, and then cover it with bonding resin. To investigate the durability of these methods, specimens were immersed in NaOCl, denture cleanser, and coffee. Photographs of the specimens were taken and RGB values were measured. Differences in durability were analyzed by Friedman test. The RGB values were significantly different between LA and DB, but those of DA changed little. The results made it clear that DA was a more durable denture marking method than LA—which is a method generally used.
Content from these authors
© 2008 The Japanese Society for Dental Materials and Devices