Dental Materials Journal
Online ISSN : 1881-1361
Print ISSN : 0287-4547
ISSN-L : 0287-4547
Dimensional change measurements of conventional and flowable composite resins using a laser displacement sensor
Taira MIYASAKAHiroyuki OKAMURA
Author information
JOURNAL FREE ACCESS

2009 Volume 28 Issue 5 Pages 544-551

Details
Abstract

The polymerization shrinkage values of commercial flowable and conventional composites were measured with a newly developed laser displacement sensor. Compressive strength and filler content were also measured. Compared to conventional composites, the flowable composites required a longer time — not exceeding 4 minutes — to reach a constant polymerization shrinkage rate. In terms of shrinkage ratio, it was less than 1.5% for conventional composites at 90 minutes, which was lower than that of flowable composites, i.e. more than 2.0%. The compressive strength of conventional composites was higher than that of flowable composites. A highly significant correlation between filler content and polymerization shrinkage at 90 minutes was observed, and polymerization shrinkage tended to decrease as filler content increased. In light of the results obtained in this study, the newly developed displacement meter with a laser displacement sensor proved to be effective for in-depth investigation of the polymerization shrinkage of dental composites.

Content from these authors
© 2009 The Japanese Society for Dental Materials and Devices
Previous article Next article
feedback