Comparative adaptation accuracy of acrylic denture bases evaluated by two different methods
Chung-Jae LEESung-Bem BOKJi-Young BAEHae-Hyoung LEE
Author information
JOURNAL FREE ACCESS

2010 Volume 29 Issue 4 Pages 411-417

Details
Abstract

This study examined the adaptation accuracy of acrylic denture base processed using fluid-resin (PERform), injection-moldings (SR-Ivocap, Success, Mak Press), and two compression-molding techniques. The adaptation accuracy was measured primarily by the posterior border gaps at the mid-palatal area using a microscope and subsequently by weighing of the weight of the impression material between the denture base and master cast using hand-mixed and automixed silicone. The correlation between the data measured using these two test methods was examined. The PERform and Mak Press produced significantly smaller maximum palatal gap dimensions than the other groups (p<0.05). Mak Press also showed a significantly smaller weight of automixed silicone material than the other groups (p<0.05), while SR-Ivocap and Success showed similar adaptation accuracy to the compression-molding denture. The correlationship between the magnitude of the posterior border gap and the weight of the silicone impression materials was affected by either the material or mixing variables.

Content from these authors
© 2010 The Japanese Society for Dental Materials and Devices
Previous article Next article