Dental Materials Journal
Online ISSN : 1881-1361
Print ISSN : 0287-4547
ISSN-L : 0287-4547
Original Papers
An eighteen-month clinical evaluation of posterior restorations with fluoride releasing adhesive and composite systems
Naotake AKIMOTOKaoru OHMORIMasao HANABUSAYasuko MOMOI
Author information
JOURNAL FREE ACCESS

2011 Volume 30 Issue 3 Pages 411-418

Details
Abstract

This study evaluated the clinical performance of a fluoride releasing restorative system (FL-Bond II & Beautifil II) in posterior restorations after 18-month placement. IRB forms were submitted with each patient approving by signing their acceptance. Seven Class I and 46 Class II restorations were placed by three clinicians in 38-patients. Each FL-Bond II & Beautifil II restoration was placed under rubber dam isolation according to manufacture’s instruction. Clinical evaluation was assessed at baseline, 6 and 18-months using modified USPHS criteria. No post-operative sensitivity was reported in any restored tooth at each patient assessment. Only slight color change with some surface staining was noted. Slight marginal changes were observed in 12 of 53-restorations —seen as step irregularities when a sharp explorer was drawn across the tooth from the enamel toward the restoration interface. Utilizing USPHS evaluation criteria, the clinical performance of each (FL-Bond II & Beautifil II) posterior fluoride releasing system was clinically acceptable at 18-month.

Content from these authors
© 2011 The Japanese Society for Dental Materials and Devices
Previous article Next article
feedback
Top