Dental Materials Journal
Online ISSN : 1881-1361
Print ISSN : 0287-4547
ISSN-L : 0287-4547
Original Papers
Development of metal-resin composite for dental magnet keepers, Part 2: Optimum 4-META content
Hiroko SOMAYukio MIYAGAWA
Author information
JOURNAL FREE ACCESS

2011 Volume 30 Issue 6 Pages 894-897

Details
Abstract
Six kinds of experimental magnetic resin composites containing SUS447J1 stainless steel particles as filler were prepared. UDMA/MAA resin with an MAA mole fraction of 0.67 was used as the matrix resin. The effects of six levels of 4-META content (2, 4, 6, 8, 10, and 12 mass%) on the setting and flexural properties were studied. The metal filler content in each paste was 90 mass%. Although working time and setting time significantly diminished with the increase of the BPO and DMPT contents, both working time and setting time satisfied the ISO 4049 requirements for all experimental levels. Flexural strength and elastic modules significantly improved with the increase of 4-META content up to 10%. The optimum 4-META content necessary to develop better composite resins for magnetic attachment has been clarified.
Content from these authors
© 2011 The Japanese Society for Dental Materials and Devices
Previous article Next article
feedback