Effects of different luting cements and light curing units on the sealing ability and bond strength of fiber posts
Nilüfer Celebi BERIATAhmet Atila ERTANZeliha YILMAZGülsah GULAYCem SAHIN
著者情報
ジャーナル フリー

2012 年 31 巻 4 号 p. 575-582

詳細
抄録
This study evaluated the sealing ability and push-out bond strength of two luting cements cured with two different types of light curing units (LCU): light-emitting diode (LED) versus quartz tungsten halogen (QTH). Forty teeth were divided into four groups(n=10/group). Quartz fiber posts (D. T. Light-Post) were luted to coronal or apical section of root canals using two types of resin cements (Panavia F or RelyX) cured with either LED LCU (Elipar FreeLight II) or QTH LCU (Optilux 501). Highest push-out bond strength was exhibited by QTH-cured RelyX, which was not significantly different from LED-cured RelyX but was higher than QTHcured Panavia F. The push-out bond strength of Panavia F did not differ with LCU type (p>0.05), but exhibited lower values than both QTH- and LED-cured RelyX. Fluid filtration test revealed that sealing ability was not influenced by luting cement type, but was signifi cantly influenced by LCU type in favor of QTH light source: QTH-cured specimens displayed better seal than LED-cured ones (p<0.05).
著者関連情報
© 2012 The Japanese Society for Dental Materials and Devices