Dental Materials Journal
Online ISSN : 1881-1361
Print ISSN : 0287-4547
ISSN-L : 0287-4547
Original Paper
Inadequate shear bond strengths of self-etch, self-adhesive systems for secure orthodontic bonding
Eren İŞMAN, Emine Şirin KARAARSLAN, Rıdvan OKŞAYAN, Ali Rıza TUNÇDEMİR, Serdar ÜŞÜMEZ, Nejdet ADANIR, Mehmet Ata CEBE
Author information
JOURNAL FREE ACCESS

2012 Volume 31 Issue 6 Pages 947-953

Details
Abstract
This study evaluated the shear bond strength (SBS) of a traditional orthodontic bracket bonding agent (Transbond XT) against two self-etch, self-adhesive systems (Maxcem Elite and Vertise Flow). Sixty premolar teeth and sixty brackets were randomly and equally divided into five groups: Transbond XT (TXT) as the control, Maxcem Elite (ME) without etching, ME with etching (ME/ Etch), Vertise Flow (VF) without etching, and VF with etching (VF/Etch). Respective SBS results of the five groups were 9.86±3.20, 4.67±2.94, 7.82±2.56, 2.55±0.77, and 7.89±1.17 MPa. SBS values of the new self-etch adhesive systems were significantly lower than the traditional etch-and-rinse control (p<0.005). However, no significant differences were found between TXT and the self-adhesives applied with etching (p>0.005). After debonding, ARI scores “0" and “1" were predominant in non-etched ME and VF groups. It was concluded that new self-etch, self-adhesive bonding systems require additional phosphoric acid application to achieve comparable SBS values as the traditional orthodontic bonding agent.
Content from these authors
© 2012 The Japanese Society for Dental Materials and Devices
Previous article Next article
feedback