Dental Materials Journal
Online ISSN : 1881-1361
Print ISSN : 0287-4547
ISSN-L : 0287-4547
Original Paper
Influence of thickness and undercut of thermoplastic resin clasps on retentive force
Hidekazu OSADAHidemasa SHIMPOTohru HAYAKAWAChikahiro OHKUBO
Author information
JOURNAL FREE ACCESS

2013 Volume 32 Issue 3 Pages 381-389

Details
Abstract

Thermoplastic resin clasps have been used for esthetic denture rehabilitation. However, details of the design of the clasps have never been thoroughly clarified. This study investigated the retentive forces of thermoplastic resin clasps for non-metal clasp dentures. The retentive forces of all thermoplastic resin clasps depended on the elastic modulus of each resin, undercuts, thickness, and widths of the tested. A clasp with more than 0.5 mm undercut and 1.0 mm thickness is needed for Valplast. Similarly, more than 0.25 mm undercut and 1.0 mm thickness and 0.5 mm undercut and 0.5 mm thickness are required for Estheshot and Reigning, respectively; thus, the recommended clasp arm thickness is 1.0 mm to 1.5 mm for Valplast and Estheshot and 0.5 mm to 1.0 mm for Reigning when the width of the retentive arm is 5.0 mm.

Content from these authors
© 2013 The Japanese Society for Dental Materials and Devices
Previous article Next article
feedback