Dental Materials Journal
Online ISSN : 1881-1361
Print ISSN : 0287-4547
ISSN-L : 0287-4547
Original Paper
Impact of surface treatment of different reinforced glass-ceramic anterior crowns on load bearing capacity
Angela EMSLANDER, Michael REISE, Marlis EICHBERGER, Julia UHRENBACHER, Daniel EDELHOFF, Bogna STAWARCZYK
Author information
JOURNAL FREE ACCESS

2015 Volume 34 Issue 5 Pages 595-604

Details
Abstract
This study investigated the influence of different surface treatments on fracture load (FL) of canine crowns fabricated from two different pressable lithium-disilicate ceramics: A (HS10PC, estetic ceram, n=180) and B (IPS e.max Press, IvoclarVivadent, n=120). The standardized specimens were divided into groups of six different surface treatments and two glazing temperatures. A-group specimens were additionally assigned two glazing pastes with various thermal expansion coefficients (TEC). FL was measured and TECs were determined. Data were analyzed using three/one-way ANOVA followed by post-hoc Scheffe’s test. B showed comparable or higher FL than A (B: 503–876 N; A: 375–734 N). Lithium-disilicate crowns show higher FL when not grinded but only polished or glazed. Glazing pastes affected FL depending on their TECs, firing temperature and crown treatment. TEC of A and B was 10 ppm/K, glazing pastes for A presented TECs of 7.5 ppm/K and 10 ppm/K and for B of 9 ppm/K.
Content from these authors
© 2015 The Japanese Society for Dental Materials and Devices
Previous article Next article
feedback