Surface roughness and gloss of current CAD/CAM resin composites before and after toothbrush abrasion
Hiroyasu KOIZUMIOsamu SAIKIHiroshi NOGAWAHaruto HIRABATomoyo OKAZAKIHideo MATSUMURA
Author information
JOURNAL FREE ACCESS

2015 Volume 34 Issue 6 Pages 881-887

Details
Abstract
The purpose of this study was to evaluate the gloss and surface roughness behaviors of newly developed CAD/CAM composite blocks with different filler contents and characteristics. The gloss and surface roughness were quantified before and after a toothbrush dentifrice abrasion test; the results were compared to the gloss and surface roughness of a ceramic CAD/CAM block. Knoop hardness was determined before abrasion test. The results were analyzed by ANOVA, Tukey HSD, and Dunnett t test (p<0.05). The rank order of Knoop hardness was as follows: Vita Mark II>Vita Enamic>Gradia block>Shofu Block HC, Lava Ultimate≥Katana Avencia block≥Cerasmart. After toothbrush abrasion, a significant difference in the gloss unit was detected between the Shofu Block HC material and the ceramic block. The Ra and Rz of the Cerasmart and Shofu Block HC materials were significantly larger than those of the ceramic block after toothbrush abrasion.
Content from these authors
© 2015 The Japanese Society for Dental Materials and Devices